The Reichert Tono-Pen XL is a handheld tonometer designed to measure intraocular pressure (IOP) effectively, primarily serving as a screening and monitoring tool for conditions such as glaucoma or suspected cases of increased IOP.

The primary purpose of the Reichert Tono-Pen XL is to provide medical professionals with a reliable and convenient method for measuring IOP. Elevated intraocular pressure can indicate various eye conditions, including glaucoma, where early detection is crucial for effective management and prevention of vision loss. The Reichert Tono-Pen XL offers a portable, accurate, and versatile solution for measuring IOP in diverse clinical settings, from traditional offices to remote locations, making it an essential tool for ophthalmologists, optometrists, technicians, and other medical professionals.

Quantity and Value

The Reichert Tono-Pen XL emphasizes both quantity and value in its features and components.

Features:

  • Easy to Use: The device ensures that IOP measurements can be reliably taken by a range of medical professionals, minimizing the need for extensive training.
  • Portable: Weighing just 2.1 ounces and battery-operated, the Reichert Tono-Pen XL offers unparalleled portability, enabling users to take fast and accurate IOP measurements anywhere.
  • Accurate: The Reichert Tono-Pen XL boasts accuracy comparable to or exceeding other electronic applanation tonometers, ensuring reliable results for clinical decision-making.
  • Versatile: Its versatility allows for use in various scenarios, including cases of irregular or high corneal astigmatism and with patients in different positions, making it suitable for a wide range of clinical settings.

Features Explanation

The Reichert Tono-Pen XL, a flagship product from Reichert Technologies, stands out as a handheld tonometer meticulously engineered to deliver precise measurements of intraocular pressure (IOP). It serves primarily to cater to the needs of medical professionals for screening and monitoring purposes in conditions such as glaucoma or suspected cases of elevated IOP.

Manufacturing Precision and Standards Compliance

Crafted with meticulous attention to detail, the Reichert Tono-Pen XL adheres to rigorous manufacturing standards set by Reichert Technologies, ensuring optimal performance and compliance with industry regulations. With 25 years of clinically proven accuracy and reliability, this device is a testament to the brand’s commitment to precision and quality.

Compatibility

Designed with compatibility in mind, the Reichert Tono-Pen XL functions seamlessly in any position, making it suitable for use on patients in beds or wheelchairs. Its portable and lightweight design, synonymous with Reichert Technologies, facilitates ease of use across various clinical settings, guaranteeing rapid and accurate IOP measurements regardless of the scenario.

Choosing the Correct Brand for Performance and Warranty:

Selecting the right brand is paramount for achieving superior performance and securing warranty coverage. With nearly two decades of global trust from clinicians, Reichert Technologies’ Tono-Pen XL has established itself as a clinically trusted tool, offering not only accurate and objective IOP measurements but also peace of mind to operators, ensuring confidence in every measurement taken.

Benefits and Advantages

The Reichert TONO-PEN® XL Tonometer offers a multitude of benefits, making it an indispensable tool for medical professionals in ophthalmology:

  • Highly Accurate Readings: The TONO-PEN XL provides IOP readings that closely correlate with Goldmann Tonometry, ensuring reliability in clinical decision-making regarding eye health.
  • Portable and Lightweight Design: Weighing a mere 2.1 ounces, the TONO-PEN XL is incredibly portable, allowing for IOP measurements to be taken with ease anywhere, on any patient, enhancing convenience and versatility.
  • Advanced Technology for Precision: Equipped with micro strain gauge technology and advanced recognition and tracking software, the TONO-PEN XL delivers precise and objective IOP measurements, minimizing operator bias and ensuring accuracy and repeatability.
  • User-Friendly Operation: With its intuitive design and easy-to-use interface, the TONO-PEN XL can be operated efficiently by medical professionals with minimal training, streamlining the measurement process and optimizing workflow.
  • Trusted by Clinicians Worldwide: For over two decades, the TONO-PEN XL has been a trusted companion for clinicians globally, attesting to its reliability and performance in real-world clinical settings.

Importance of Certifications and Quality Checks

The importance of certifications and quality checks cannot be overstated when it comes to medical devices. The TONO-PEN XL undergoes rigorous quality assurance measures to ensure compliance with industry standards and regulations, providing assurance of its reliability, accuracy, and safety. With certifications from regulatory bodies and adherence to stringent quality control protocols, users can have confidence in the TONO-PEN XL’s performance and trust its readings for critical clinical decisions regarding intraocular pressure management and eye health.

Step-by-Step Usage Guide

  • Device Indication:
    1. The Tono-Pen XL tonometer, a prescription-only device, is intended for measuring intraocular pressure (IOP) during routine eye examinations or when elevated intraocular pressure is suspected by properly trained eyecare professionals, including ophthalmologists, optometrists, opticians, and eye care technicians.
  • Setup:
    1. Battery Installation: The Tono-Pen XL tonometer is shipped without batteries installed. Install four OCU-CEL 3.0 volt lithium manganese dioxide batteries, ensuring correct polarity.
    2. Tonometer Preparation: Allow the instrument to stabilize at room temperature for approximately 30 minutes. Attach an Ocu-Film + Tip Cover securely onto the Transducer Assembly.
    3. Calibration: Perform calibration once daily before initial use or in case of unanticipated readings. Follow the calibration procedure outlined in the manual.
  • Performing IOP Measurements:
    1. Patient Preparation: Instill topical anesthetic onto the eye to be examined. Position the patient comfortably with eyes fully open and fixated on a point of reference to minimize eye movement.
    2. Measurement Procedure: Hold the Tono-Pen XL perpendicular to the patient’s cornea, ensuring proper positioning and stability. Depress the Operator’s Button once to initiate measurement. Gently tap the corneal surface with the probe tip.
    3. Result Display: Valid IOP readings will be displayed digitally on the LCD, accompanied by audible cues. Four valid readings will be averaged and displayed along with statistical reliability indicators.
    4. Post-Measurement: Replace the Ocu-Film Tip Cover before using the tonometer on another patient or for storage.

Precautions and Considerations

  • Latex Allergy Warning: Ocu-Film contains natural rubber latex, which may cause allergic reactions. Ensure patients are questioned about latex allergies before examination.
  • Cross-Contamination Prevention: Do not reuse Ocu-Film Tip Covers on multiple patients to prevent cross-contamination.
  • Proper Handling: Follow proper handling procedures to avoid damaging the device or affecting measurement accuracy.
  • Calibration: Ensure calibration is performed daily and as indicated to maintain measurement accuracy.
  • Battery Usage: Use only recommended batteries and follow correct installation procedures to prevent damage to the device.
  • Eyecare Professional Supervision: Ensure that only properly trained eyecare professionals use the Tono-Pen XL tonometer for accurate and reliable measurements.

Technical Details and Material Information

  • Dimensions: The Tono-Pen XL measures 7 1/4” x 1” x 7/8” (18.42 x 2.54 x 2.22 cm) and weighs 2.1 oz. (59.4 g).
  • Electrical Requirements: It operates on 2 x 3V Lithium Manganese Dioxide batteries (OCU-CEL). The Tono-Pen XL contains natural rubber latex in the OCU-FILM + Tip Cover.
  • Software Revision: The software revision can be obtained by contacting Reichert Technologies. The serial number provides access to the software version.
  • Regulatory Classification: Internally powered with 6V battery insulation protection, IPX0 ingress protection, BF applied part type, and continuous mode of operation.

Quality Control Measures

  • Environmental Requirements:
    • Operational Environment: Temperature range of 15° to 35°C (59° to 95°F), relative humidity range of 30 to 75%, and atmospheric pressure range of 80 kPa to 106 kPa (23.6 to 31.3 in.Hg).
    • Transport and Storage Environment: Temperature range of -10° to 60°C (14° to 140°F), relative humidity range of 10 to 80% (non-condensing), and atmospheric pressure range of 50 kPa to 106 kPa (14.8 to 31.3 in.Hg).

Expiry or Optimal Usage Dates:

  • The Tono-Pen XL is warranted against defective material and workmanship under normal use for one year from the date of invoice to the original purchaser. This warranty covers repair or replacement of defective parts or products at Reichert’s discretion.
  • Expendable items such as lamps, bulbs, charts, cards, and other consumables are not covered by the warranty.
  • All claims under warranty must be in writing and accompanied by a copy of the purchaser’s invoice.
  • Reichert reserves the right to make changes in design or improvements to its products without obligation to add such to previously manufactured products.
Note: The Tono-Pen XL should be used strictly in accordance with the applicable Reichert instruction manual and by trained eyecare professionals to ensure proper functioning and accurate results.

Compatibility and Versatility

The Reichert Tono-Pen XL tonometer boasts remarkable compatibility, ensuring seamless integration with various models and setups commonly found in clinical environments. Whether utilized alongside traditional diagnostic equipment or integrated into modern digital systems, the Tono-Pen XL’s precision and reliability remain uncompromised. Its adaptable design allows for easy incorporation into existing workflows, making it a preferred choice for ophthalmologists, optometrists, and eye care technicians seeking compatibility across different instruments and setups.

Renowned for its versatility, the Reichert Tono-Pen XL tonometer finds applications across a spectrum of clinical settings and scenarios. From routine eye examinations to specialized glaucoma clinics, from hospital bedside use to remote locations, its lightweight and portable design ensures flexibility without sacrificing accuracy or efficiency. Whether measuring intraocular pressure in seated or supine patients, the Reichert Tono-Pen XL delivers consistent and reliable results, making it an indispensable tool for eye care professionals worldwide.

Pricing Information

Get the current generation Reichert Tono-Pen® XL at an unbeatable price of $2,795.00. This professionally refurbished device comes with precision calibration and performance, ensuring superior quality.

With every purchase of our refurbished Tono-Pen® XL, you’ll benefit from FREE Priority Express shipping. Each package includes a deluxe case, additional batteries, a sturdy metal stylus, and comprehensive maintenance and operational guides. Plus, enjoy peace of mind with our 15-month assurance, ensuring your satisfaction and confidence in our product.

Upgrade your tonometry experience today and enjoy top-notch quality, affordability, and convenience with the Reichert Tono-Pen® XL.

FAQs

1. What is the Tono-Pen XL tonometer used for?

The Tono-Pen XL is a handheld device designed for measuring intraocular pressure (IOP) during routine eye examinations or when elevated intraocular pressure is suspected. It is primarily used by ophthalmologists, optometrists, and eye care technicians for screening and monitoring conditions such as glaucoma.

2. What are the key features of the Tono-Pen XL?

The Tono-Pen XL offers easy-to-use functionality, portability, accuracy, and versatility. Its advanced microprocessor technology ensures precise and reliable IOP measurements, making it suitable for use in various clinical settings.

3. How does the Tono-Pen XL compare to other tonometers?

The Tono-Pen XL boasts accuracy comparable to or exceeding other electronic applanation tonometers, providing reliable results for clinical decision-making. Its design allows for measurements in any orientation, making it ideal for use with patients in beds or wheelchairs.

4. Is the Tono-Pen XL compatible with different models?

Yes, the Tono-Pen XL tonometer is compatible with various models commonly found in clinical environments. Its adaptable design allows for seamless integration into existing setups, ensuring compatibility across different instruments.

5. What is the pricing for the Tono-Pen XL?

The current generation Reichert Tono-Pen® XL is priced at $2,795.00. This professionally refurbished device comes with precision calibration and performance, backed by a 15-month warranty. Additional perks include FREE Priority Express shipping and a deluxe package with essential accessories.

6. Are there bulk purchase options available?

Yes, bulk purchase options are available for those looking to equip their practice or clinic. Contact us directly to discuss special pricing and tailored solutions for bulk orders, ensuring affordability and convenience for your needs.

7. What warranty and support options are provided?

The Tono-Pen XL comes with a 15-month warranty, providing assurance of its quality and performance. Additionally, comprehensive maintenance and operational guides are included with every purchase, ensuring proper usage and longevity of the device.

8. How can I obtain software revisions and technical support?

Software revisions can be obtained by contacting Reichert Technologies directly. Technical support and assistance are also available through Reichert’s authorized service centers or dealers, ensuring prompt resolution of any queries or issues.

Contact Information

Corporate Office:

10115 E. Bell Rd. Ste 107-162 Scottsdale, AZ 85260

Toll Free / Fax 877.446.1166

Additional Offices:

332 Forest Ave. #18 Laguna Beach, CA 92651 949.715.9992

29226 Oceanside Dr. Rancho Palos Verdes, CA 90275

Elkridge, MD

Phone: (877) 446-1166

Email: richard@ikisstc.com

Company Background and Commitment

iKiSS is a leading provider of top-quality refurbished medical equipment, specializing in Tono-Pen® Tonometers, Tono-Pen AVIA® Tonometers, Slit Lamps, and Phoropters. With a commitment to delivering excellence, iKiSS offers substantial savings of up to 40% on refurbished devices without compromising on quality. Our mission is to provide healthcare professionals with reliable, cost-effective solutions that enhance patient care and practice efficiency.

At iKiSS, customer satisfaction is our top priority. We guarantee 100% satisfaction with every purchase, standing behind the quality and reliability of our products. Our commitment to excellence extends beyond offering competitive pricing – it encompasses our industry-leading warranty and dedication to service and maintenance.

Warranty:

iKiSS boasts the #1 warranty in the industry for refurbished medical devices. Our products undergo thorough refurbishment and testing to meet the highest quality standards, ensuring reliability and performance. We offer warranties ranging from 6 months to 15 months, depending on the product:

  • Tono-Pen AVIA® Tonometers: 15 months
  • Medtronic Pens: 15 months
  • Reichert Pens: 15 months
  • Slit Lamps: 1 year
  • Phoropters: 1 year

Who Is Covered by the Warranty:

The warranty extends to the original purchaser only and is non-transferable. This ensures that our commitment to quality and service is upheld for every customer.

What Is Covered by the Warranty:

iKiSS warrants its products against defects in material or workmanship under normal use, service, and maintenance. We stand behind our products and will replace any defective parts or products at no charge within the warranty period. If a replacement is not feasible, we may offer a refund in exchange for the return of the product in its original packaging.

Exclusions:

The warranty does not cover malfunctions or damage resulting from improper maintenance, misuse, abuse, negligence, accident, or alteration. We encourage proper care and usage of our products to ensure their longevity and performance.

At iKiSS, our commitment to quality, reliability, and customer satisfaction drives everything we do. Trust us for all your medical equipment needs, and experience the iKiSS difference firsthand.

Summary:

iKiSS is your trusted source for top-quality refurbished medical equipment, including Tono-Pen® Tonometers, Tono-Pen AVIA® Tonometers, Slit Lamps, and Phoropters. With a commitment to excellence, iKiSS offers substantial savings of up to 40% without compromising on quality. Our products undergo rigorous refurbishment and testing to meet the highest standards, ensuring reliability and performance.

We pride ourselves on offering the #1 warranty in the industry for refurbished devices, providing customers with peace of mind and confidence in their purchases. Our warranty covers defects in material or workmanship and extends from 6 months to 15 months, depending on the product.

At iKiSS, customer satisfaction is our priority. We guarantee 100% satisfaction with every purchase, backed by our commitment to quality, reliability, and service. Whether you’re a healthcare professional or a medical facility, trust iKiSS for all your medical equipment needs.

Ready to upgrade your medical equipment?

Visit iKiSS now to browse our selection of refurbished Tono-Pen® Tonometers, Tono-Pen AVIA® Tonometers, Slit Lamps, and Phoropters. With our #1 warranty in the industry and 100% satisfaction guarantee, you can trust iKiSS for reliable, cost-effective solutions.

Don’t miss out – experience the iKiSS difference today!